Arcom

Drypoint

DRYPOINT AC - Düşük işletme maliyetli Adsorpsiyon kurutucusu

Size sağladığı avantajları 

  • Belirgin bir şekilde işletme maliyetlerinizi düşürür
  • Yüksek çalışma güvenliği
  • Kolay bakım yapabilme
  • Basit montaj
  • Sipariş üzerine özel üretim

The operation of compressed air systems with conventional adsorption dryers suffers from system-related pressure drop. This deficiency needs to be compensated via an increased compressor performance, this requiring a higher energy demand. 
Cold-regenerated DRYPOINT AC adsorption dryers offer a convincing solution to the problem: 
BEKO has developed an adsorption dryer which limits the pressure drop to an average of only 0.25 bar, including the pre- and final filters.- Compared with conventional constructions, this represents an improvement of over 50%. 
Thus, acquisition costs will be repaid through energy savings costs after an average of only three years.

DRYPOINT AC adsorption dryers are available in two series:

  • performance range 10 - 112 m³/h
  • performance range 135 - 1.550 m³/h
Technical Data
Range 10 - 112 m³/h

Max. operating overpressure

16 bar

PDP default setting (outlet)

 - 40° C

PDP optional

at 70% of nominal capacity:
-70°C

Inlet temperature air

2° C / 50°C min./max.

Ambient temperature

5° C / 50°C min./max.

Electric power supply

100-240 VAC, 50-60 Hz;
12 - 24 VDC

Other voltages on request

Inlet filter

0,01 µm , 0,01 mg/m³

integrated dust filter

1,0 µm

 

Connection

Volume flow

Dimensions

Weight

 

 

m³/h

scfm

A

B

C

D

E

kg

AC 119

G 3/8

10,2

6

504

281

92

-

-

14

AC 122

G 3/8

13,6

8

565

281

92

-

-

15

AC 126

G 3/8

17,0

10

635

281

92

-

-

16,5

AC 136

G 3/8

25,5

15

815

281

92

-

-

19,5

AC 148

G 3/8

37,4

22

1065

281

92

-

-

24

AC 171

G 3/8

56,1

33

1460

281

92

-

-

31

AC 191

G 1/2

74,8

44

1065

281

184

-

-

47

AC 196

G 1/2

112,2

66

1460

281

184

-

-

61

Performance data in accordance with DIN ISO 7185 relate to an input pressure of 7 bar (0) and an inlet temperature of 35 °C. Please multiply by the appropriate corrective factors where the input conditions deviate.

The regeneration air portion depends on the actual operating conditions. At a system pressure of 7 bar, the average demand for regeneration air amounts to approximately 15%.


Corrective factors pressure / temperature

bar

4

5

6

7

8

9

10

11

12

13

14

15

16

35°C

0,63

0,75

0,88

1,00

1,13

1,25

1,38

1,50

1,63

1,75

1,88

2,00

2,12

40°C

0,55

0,66

0,77

0,88

0,99

1,10

1,21

1,32

1,43

1,54

1,65

1,76

1,87

45°C

0,42

0,50

0,59

0,67

0,76

0,84

0,92

1,01

1,09

1,17

1,26

1,34

1,42

50°C

0,35

0,41

0,48

0,55

0,62

0,69

0,76

0,83

0,90

0,96

1,03

1,10

1,17

 

Technical Data
Range 135 - 1.550 m³/h

Max. operating overpressure

AC 205 - AC 250: 16 bar
AC 260 - AC 295: 10 bar
(16 bar optional)

Higher nominal output on request

PDP default setting (outlet)

- 40° C

PDP optional

-20° C / -70°C

Inlet temperature air

2° C / 50°C min./max.

Ambient temperature

5° C / 50°C min./max.

Electric power supply

100-240 VAC, 50-60 Hz;
24 VDC

Other voltages on request

Input filter

0,01 µm

Output filter

1,0 µm

Protection class

IP 54

Extra-protection against splashes of water.

 

Connection

Volume flow

Dimensions

Weight

 

 

m³/h

scfm

A

B

C

D

E

kg

AC 205

G1

135

79,5

1610

780

530

1430

755

190

AC 210

G1

155

91,2

1800

780

530

1620

755

255

AC 215

G1

200

117,7

1500

780

530

1310

755

280

AC 220

G1,5

280

164,8

1520

980

635

1310

910

360

AC 225

G1,5

380

223,7

1820

980

635

1590

910

440

AC 230

G1,5

500

294,3

1800

980

635

1590

910

550

AC 240

G 2

630

370,8

1840

980

635

1580

1000

640

AC 250

G 2

800

470,9

1860

1360

940

1565

1000

820

AC 260

G 2,5

1000

588,6

1840

1360

940

1515

1140

950

AC 275

G 2,5

1250

735,7

1830

1360

940

1525

1140

1100

AC 295

G 2,5

1550

912,3

1900

1360

940

1555

1140

1230

Performance date according to DIN ISO 7185 relate to an input pressure of 7 bar (overpressure) and an inlet temperature of 35°C. Please multiply with the corrective factors where the input conditions deviate.

Corrective factors pressure / temperature

bar

4

5

6

7

8

9

10

11

12

13

14

15

16

35°C

0,63

0,75

0,88

1,00

1,13

1,25

1,38

1,50

1,63

1,75

1,88

2,00

2,12

40°C

0,55

0,66

0,77

0,88

0,99

1,10

1,21

1,32

1,43

1,54

1,65

1,76

1,87

45°C

0,42

0,50

0,59

0,67

0,76

0,84

0,92

1,01

1,09

1,17

1,26

1,34

1,42

50°C

0,35

0,41

0,48

0,55

0,62

0,69

0,76

0,83

0,90

0,96

1,03

1,10

1,17


Regeneration air in %

PDP - 20°C Outlet

18,0

15,4

12,9

11,3

10,0

9,1

8,2

7,6

7,0

6,5

6,0

5,6

5,3

PDP - 40°C Outlet

24,0

20,5

17,1

14,8

13,3

12,1

10,9

10,1

9,2

8,6

8,0

7,4

7,1

PDP - 70°C Outlet

26,7

22,8

19,0

16,7

14,8

13,4

12,1

11,2

10,3

9,6

8,9

8,4

7,9